15 integrations
Connections integrations
Read and write PLC tags, and send results to SCADA, databases and any API.
/
- AVEVA InTouch and System PlatformShow detections, counts and pass or fail results in AVEVA InTouch and System Platform as live tags, served from Roboflow's OPC UA Server on your edge device.
- AVEVA PI SystemStore detections, counts and pass or fail results as PI points, collected from your edge device over OPC UA with the AVEVA Adapter or PI Connector for OPC UA.
Allen-Bradley PLCsRead and write ControlLogix, CompactLogix and Micro800 tags over EtherNet/IP, so a detection can reject a part, hold a station or count output.
- IgnitionWrite detections, counts and pass or fail results from Roboflow Workflows into Ignition tags over OPC UA or MQTT, for Perspective screens, history and alarms.
- Kepware ServerWrite detections, counts and pass or fail results into Kepware Server tags over OPC UA, so every device and client connected to Kepware can use them.
- Matrikon OPCWrite detections, counts and pass or fail results to MatrikonOPC servers through Matrikon OPC UA Tunneller, so the devices and clients behind them can use them.
- Microsoft SQL ServerInsert detections, counts and pass or fail results from Roboflow Workflows as rows in a Microsoft SQL Server table, ready for reports, dashboards and other systems.
- Mitsubishi MELSEC PLCsRead and write MELSEC iQ-F devices over Modbus TCP, so a detection can reject a part, hold a station or count output on FX5 PLCs.
- Modbus TCPRead and write coils and registers on any Modbus TCP device, so a detection can reject a part, signal a robot or count output.
OBSRun a Roboflow model on your OBS Studio output in the browser and switch scenes or move sources when it detects a gesture.- Omron NX/NJ controllersRead and write Omron NX and NJ controller values over Modbus TCP, so a detection can reject a part, hold a station or count output.
- Process HistoriansLog detections, counts and pass or fail results in AVEVA PI, Canary, FactoryTalk Historian and other historians, collected over OPC UA from your edge device.
- Robot controllersSend pick, sort and reject signals to Universal Robots and FANUC controllers over Modbus TCP, and read their status back into a Workflow.
- Siemens S7 PLCsRead and write S7-300, S7-400, S7-1200 and S7-1500 data through PLC Relay, so a detection can reject a part, hold a station or count output.
ZapierRun Roboflow models inside Zaps with the Roboflow app on Zapier, or send Workflow results to a Zapier webhook to act on them in thousands of apps.
Don’t see your tool?
Roboflow imports and exports the common annotation formats and has a REST API and Python SDK, so most stacks connect without a dedicated integration.













