Roboflow + Siemens S7 PLCs

Read and write S7-300, S7-400, S7-1200 and S7-1500 data through PLC Relay, so a detection can reject a part, hold a station or count output.

Siemens S7 is the SIMATIC family of PLCs, including the S7-300, S7-400, S7-1200 and S7-1500, which hold their data in data blocks and memory areas reached over S7 communication on port 102.

Roboflow reaches them through PLC Relay, a service on your edge device that speaks the S7 protocol and holds the PLC address and tag list. In a Workflow, PLC Writer sends a result, such as a reject flag or a defect count, to an address like DB1.DBX0.0, and PLC Reader pulls values such as a part-present bit into the Workflow. Because the relay owns the connection, the same Workflow runs on every line.

How to connect Siemens S7 PLCs to Roboflow

6 steps
  1. Set up an edge device

    Register a device in Deployment Manager and connect it to the same network as the PLC, with port 102 reachable. The device runs your Workflows on site.

  2. Prepare the PLC in TIA Portal

    On an S7-1200 or S7-1500, enable PUT/GET access and turn off optimized block access on each data block the relay will read or write.

  3. Add the PLC Relay

    On the device's Configuration tab, add the PLC Relay service, choose Siemens S7 and enter the PLC's IP address, rack (0 to 7) and slot (0 to 31).

  4. Define your tags

    Add each tag by its address, such as DB1.DBX0.0 for a BOOL, DB1.DBW0 for an INT, DB1.DBD0 for a DINT or REAL, or M0.0 for a merker bit, and mark the tags the Workflow may write. Simulation mode lets you test without hardware.

  5. Add PLC blocks to the Workflow

    Add a PLC Reader to bring values in and a PLC Writer to send results out, both in Roboflow PLC Relay connection mode and pointed at the relay.

  6. Deploy and monitor

    Deploy the Workflow to a stream on the device. The device page shows the relay's connection state and live tag values, and a PLC Disconnected alert tells you if the link drops.

What teams build with Siemens S7 PLCs

  • Reject a defective part

    Write a reject bit when the Workflow finds a defect, and let the PLC fire the reject mechanism at the right moment.

  • Inspect only when a part is there

    Read a part-present bit and run the inspection only when the PLC says a part is in front of the camera.

  • Count output per shift

    Write running counts of good and rejected parts to DINT values in a data block the PLC and HMI already use.

Works with

ProductHow Roboflow connects
S7-1200 and S7-1500PLC Relay, with PUT/GET on
S7-300 and S7-400PLC Relay
Siemens WinCCVia the PLC tags

Questions

No. PLC Relay, running on your edge device, speaks the S7 protocol to the controller itself.

On S7-1200 and S7-1500 controllers, enable PUT/GET access and turn off optimized block access on the data blocks the relay uses. Without these, the PLC refuses the connection.

Yes. The PLC Reader block brings values such as a part-present bit or a recipe number into the Workflow, where they can gate or label each inspection.

No. PLC Relay and the PLC blocks run on your own device on the plant network, close to the camera and the controller, not on Roboflow's hosted API.

The PLC blocks and PLC Relay are part of the Enterprise plan. Talk to our team to add them to your workspace.

Why are companies choosing Roboflow?

The end-to-end platform for vision AI: create datasets, train models and deploy to production.

  • Flexible deployment modes

    Move from a scalable cloud API to edge hardware like NVIDIA Jetson without managing complex dependencies.

  • Integrated workflow builder

    Combine multiple AI models, custom business logic and third-party integrations into one production-ready pipeline in a low-code editor.

  • Model monitoring and alerts

    Dashboards track confidence, inference time and request volume for your deployed models, and email alerts tell your team when confidence suddenly drops.

View all
Get started

Build on the Platform

For developers, engineers, and technical founders who want to get hands on. Try the free tier; the docs are open.

Bring it into your operation

For heads of AI, operations leaders, and enterprise teams. Bring a known problem, or work with us to find the first one worth taking on.