Bring real-time intelligence to every tonne that crosses the tipping floor with Roboflow Vision AI for lithium battery detection. Built for materials recovery facilities, e-waste processors, transfer stations, and scrap yards where one crushed cell in the baler, shredder, or compactor can start a fire that stops the plant for days. Fire Rover counted 448 publicly reported fires at waste and recycling facilities in 2025 and put the damage at about $2.5 billion, and the industry's own survey work names small discarded batteries as the largest known cause.
Find batteries in the stream before they are crushed:
- Detect loose cells, pouch and cylindrical packs, power banks, vapes, cordless tool batteries, and battery-powered toys and electronics on the pre-sort belt with a model trained on your own footage, in the dust, glare, and clutter of a real line.
- Watch the tipping floor as loads are pushed out, where the EREF survey found more fires start than anywhere else, and flag a battery or a swollen, charred pack before the loader buries it.
- Separate batteries from the cans, foil, and small electronics that look similar at belt speed, so the alert fires on a cell and not on every shiny object, the same way foreign object detection works on a production line.
Protect the baler, shredder, and the whole building:
- Put a last check on the feed to the baler, shredder, or compactor, so a battery that got past the sorters is caught before it is crushed.
- Run thermal hot-spot detection on storage bunkers and bale rows, and fire and smoke detection across the floor, in the same Workflow, so a cell that was missed still gets caught when it starts to heat.
- Extend the same cameras to waste sorting and contamination checks, so one installation serves safety, quality, and throughput.
Trigger the right response and keep the record:
- Alert the pre-sort station with a light, a screen, or a tablet, showing the frame and where on the belt the battery is, so a sorter can pull it in time.
- Send a slow or stop signal to the belt PLC ahead of the baler or shredder when a battery is confirmed on a load already on its way.
- Log every detection with a clip, line, timestamp, and the route or customer that delivered the load, so outreach and contamination fees go to the sources that keep sending batteries.
Bring intelligence to every line today. Stop a discarded battery from becoming a baler fire, a lost shift, and an insurance claim.
Frequently asked questions
What is lithium battery detection with Vision AI?
Lithium battery detection with Vision AI uses cameras over the tipping floor, pre-sort belt, e-waste line, and baler feed and a trained computer vision model to find lithium-ion cells, packs, power banks, vapes, and battery-powered devices in mixed waste and recyclables. When the model finds one, it alerts the sorters, can slow or stop the belt, and logs the event with a clip. It is the safety counterpart of waste sorting and runs on the same cameras.
Why are batteries such a problem for recycling and waste facilities?
A lithium-ion cell that is crushed, punctured, or shorted in a baler, shredder, compactor, or collection truck can go into thermal runaway and ignite the material around it. The EPA documented 245 battery-caused or likely battery-caused fires at 64 waste facilities between 2013 and 2020, and the EREF survey of the sector found that small discarded batteries were the largest identifiable cause of facility fires, most of them small rechargeable lithium-ion cells, with the tipping floor the most common place a fire starts. Fire Rover counted 448 publicly reported fires in 2025 with about $2.5 billion in damage, and notes that reported fires are a fraction of the real total.
Can Vision AI find a small battery on a fast, cluttered belt?
Yes, with a model trained on your own line. Batteries are small and often half-buried, so the camera, lens, and lighting over the belt matter as much as the model: a camera close enough that a AA cell covers enough pixels, a fast shutter to stop motion blur, and even light across the belt. A detection model trained on frames from your pre-sort line learns cells, packs, vapes, and devices against your material, and a second camera at the baler feed catches what the first one missed.
Does lithium battery detection support our fire protection and safety programs?
Lithium battery detection supports the fire prevention plans, OSHA safety programs, and insurer risk reviews facilities already run by adding an early detection layer ahead of the equipment where fires start, and by keeping a record of every battery found, where it was found, and what was done. Roboflow serves as the detection engine, and your plant, safety, and fire protection teams own the response procedures, from how a sorter pulls a battery to when the belt stops.
Can it integrate with our belt controls, fire detection, and reporting?
Yes. Roboflow Workflows write detection events to a PLC tag over OPC UA or Modbus TCP, publish them over MQTT, or send a webhook, so the belt can slow, a stack light can fire, and the sorter's screen can show the frame. Events and clips can be sent to SCADA and historians, to Slack or email, and to a database for route-level reporting, so battery counts by customer and route feed the outreach that cuts the problem at the source.